By early December, we expect a single-cabinet test system ("Phase 0") to be delivered
to NCSA, and plan to allow participating science team members access to it during the Fall
PRAC Workshop (Dec. 13).  This system will have 52 XE6 compute nodes (832 AMD Interlagos
"Bulldozer" cores) and 32 XK6 compute nodes (256 Interlagos cores plus 32 Fermi accelerators),
all in the same interconnect fabric.


Early next year, a substantial (>1.3 PFLOP peak) system ("Phase 1") will be delivered to NCSA for early science
runs and possibly some porting and tuning.  This system will be available for a few months, after
which it will be integrated with the rest of the cabinets comprising the full Blue Waters system.
By early January, we will send out detailed information on the process for getting access to
the early science system.


The table below summarizes the key parameters of the various Phases of the
The table below summarizes the key parameters of the various Phases of the
Line 17: Line 7:


https://wiki.ncsa.illinois.edu/display/BWpublic/User+Information
https://wiki.ncsa.illinois.edu/display/BWpublic/User+Information
<pre>
System Components
UIUC/NCSA
Blue Waters
Phase I System
UIUC/NCSA
Blue Waters
Phase II System
UIUC/NCSA
Blue Waters
Phase III System
System
XE6
XE6/XK6
XE6/XK7
Cabinets – XE6
47
237
237
Cabinets – XK6
0
32
32
Cabinets – XIO
1
7
7
x86 Peak Performance (PF)
1.41
7.62
7.62
GPU Peak Performance (PF)
0
0
> 4
Peak Performance (PF)
1.41
7.62
>11.5
Compute Nodes – XE6
4,512
22,752
22,752
Compute Nodes – XK6
0
3,072
3,072
x86 Compute Cores
72,192
388,608
388,608
Service and I/O Nodes (total)
96
672
672
-    LNET Routers
50
582
582
-    Network
4
8
8
-    Boot
1
2
2
-    SDB
1
2
2
-    Internal Only XIO nodes
2
4
4
-    Unassigned
38
74
74
XE6 Compute Node Perf (GF)
313.6
313.6
313.6
XK6 Compute Node (GF)
NA
156.8 (CPU)
156.8(CPU) + >1,000(GPU)
Compute Node Memory (XE6/XK6)
64/32
64/32
64/32
XE6 Compute Node Memory Bandwidth (GB/s)
102.4
102.4
102.4
XK6 Compute Node Memory Bandwidth (GB/s)
51.2
51.2
51.2+>140
Total System Memory (TB)
282
1,518
1,518
Interconnect Architecture
3D Torus
12x8x24
3D Torus
23x24x24
3D Torus
23x24x24
Peak Node Injection Bandwidth (GB/s)
9.6
9.6
9.6
Average Bisection
Bandwidth (TB/s)
8.65
17.55
17.55
Minimum Bisection
Bandwidth (TB/s)
7.50
10.35
10.35
Peak Interconnect Injection Bandwidth (GB/s)
44.24
254.36
254.36
Storage Cabinets
>2
>30
>30
Total Raw Storage (PB)
>2.5
>30
>30
Total Usable Storage (PB)
>2
>25
>25
Storage SSUs
Disks
>17000
>17000
External Login Nodes
2
4
4
External Data Movers (esDM)
40
100
100
Peak Power (MW)
2.7
15.7
15.7
Power (Linpack) (MW)
2.4
< 13.6
13.6
Power (Applications) (MW)
2.2
< 12.6
12.75
</pre>

Revision as of 18:17, 3 December 2012


The table below summarizes the key parameters of the various Phases of the Blue Waters system. Phase 2 is expected to go into production in Summer 2012, and in Fall 2012, the Phase 3 system will have Kepler accelerators installed in the XK nodes. For more details, see the newly revised Blue Waters PRAC wiki page:

https://wiki.ncsa.illinois.edu/display/BWpublic/User+Information