<nowiki>Insert non-formatted text here</nowiki>'''RSQSim Paramter Sweep List'''
+
'''RSQSim Paramter Sweep List'''
  
Default Parameters:
+
Default Parameters: <br>
• A_1 = 0.01
+
• A_1 = 0.01<br>
• fA = 0.1
+
• fA = 0.1<br>
• B_1 = 0.015
+
• B_1 = 0.015<br>
• Dc_1 = 1.0e-05
+
• Dc_1 = 1.0e-05<br>
• mu0_1 = 0.6
+
• mu0_1 = 0.6<br>
• tau0_1 = 60
+
• tau0_1 = 60<br>
• sigma0_1 = 100
+
• sigma0_1 = 100<br>
• ddotEQ_1 = 1
+
• ddotEQ_1 = 1<br>
• stressOvershootFactor = 0.1
+
• stressOvershootFactor = 0.1<br>
  
Optional Slip Weakening Parameters:
+
Optional Slip Weakening Parameters:<br>
• muAmp = 0.2
+
• muAmp = 0.2<br>
• muInvDist = 2.0
+
• muInvDist = 2.0<br>
  
Physical Parameters (w/range of values):
+
Physical Parameters (w/range of values):<br>
1. Rate constitutive parameter (A_1)*    ~0.01 – 0.006
+
1. Rate constitutive parameter (A_1)*    ~0.01 – 0.006<br>
2. State constitutive parameter (B_1)*  ~0.008 – 0.0015
+
2. State constitutive parameter (B_1)*  ~0.008 – 0.0015<br>
3. Initial shear stress (tau0_1)  ~60MPa – 120MPa
+
3. Initial shear stress (tau0_1)  ~60MPa – 120MPa<br>
4. Initial normal stresses (sigma0_1)  ~100MPa – 200MPa
+
4. Initial normal stresses (sigma0_1)  ~100MPa – 200MPa<br>
5. Coefficient of friction (mu0_1)  ~0.5 – 0.7
+
5. Coefficient of friction (mu0_1)  ~0.5 – 0.7<br>
6. Critical slip distance (Dc_1)  ~1e-4 – 1e-5
+
6. Critical slip distance (Dc_1)  ~1e-4 – 1e-5<br>
  
Simulation Parameters (w/range of values):
+
Simulation Parameters (w/range of values):<br>
1. Rupture slip speed (ddtotEQ)  ~1 m/s – 2 m/s
+
1. Rupture slip speed (ddtotEQ)  ~1 m/s – 2 m/s<br>
2. Stress Overshoot Factor    ~0.1 – 0.3
+
2. Stress Overshoot Factor    ~0.1 – 0.3<br>
3. A-reduction Factor (fA)  ~0.1 – 0.3
+
3. A-reduction Factor (fA)  ~0.1 – 0.3<br>
  
 
∗Stress drop scales as (b-a)x σ, so holding (b-a)x σ=0.5MPa while changing a or b is best. We could then only vary one parameter (a or b).
 
∗Stress drop scales as (b-a)x σ, so holding (b-a)x σ=0.5MPa while changing a or b is best. We could then only vary one parameter (a or b).

Revision as of 19:56, 8 May 2017

RSQSim Paramter Sweep List

Default Parameters:
• A_1 = 0.01
• fA = 0.1
• B_1 = 0.015
• Dc_1 = 1.0e-05
• mu0_1 = 0.6
• tau0_1 = 60
• sigma0_1 = 100
• ddotEQ_1 = 1
• stressOvershootFactor = 0.1

Optional Slip Weakening Parameters:
• muAmp = 0.2
• muInvDist = 2.0

Physical Parameters (w/range of values):
1. Rate constitutive parameter (A_1)* ~0.01 – 0.006
2. State constitutive parameter (B_1)* ~0.008 – 0.0015
3. Initial shear stress (tau0_1) ~60MPa – 120MPa
4. Initial normal stresses (sigma0_1) ~100MPa – 200MPa
5. Coefficient of friction (mu0_1) ~0.5 – 0.7
6. Critical slip distance (Dc_1) ~1e-4 – 1e-5

Simulation Parameters (w/range of values):
1. Rupture slip speed (ddtotEQ) ~1 m/s – 2 m/s
2. Stress Overshoot Factor ~0.1 – 0.3
3. A-reduction Factor (fA) ~0.1 – 0.3