This page documents the High-F activities and decisions for the 2018 verification and validation runs for three groups: Olsen et al. (AWP), Graves (RWG) and Taborda et al. (Hercules).
 
This page documents the High-F activities and decisions for the 2018 verification and validation runs for three groups: Olsen et al. (AWP), Graves (RWG) and Taborda et al. (Hercules).
  
== Mesh Generation Rules ==
+
== Mesh Generation Rules and Parameter Constraints ==
 
Parameter constraints
 
Parameter constraints
 
Velocities (fixing the CVM for meshing purposes)
 
Velocities (fixing the CVM for meshing purposes)
1. Set Min Vs=500 m/s
+
* 1. Set Min Vs=500 m/s
2. If Vs was lower than 500 m/s and adjusted, then adjust Vp with original Vp/Vs ratio (so that we don’t have the automatic Vs/Vp of 3). We may want to set a minimum value of Vp (Rob to check)
+
* 2. If Vs was lower than 500 m/s and adjusted, then adjust Vp with original Vp/Vs ratio (so that we don’t have the automatic Vs/Vp of 3). We may want to set a minimum value of Vp (Rob to check)
3. Then set Max Vp/Vs= 3, if  lower Vp to maintain the max of 3 ratio
+
* 3. Then set Max Vp/Vs= 3, if  lower Vp to maintain the max of 3 ratio
 +
 
 
Lame parameters: mu and lambda (fixing the CVM for meshing purposes)
 
Lame parameters: mu and lambda (fixing the CVM for meshing purposes)
Rob check if raw model produces lambda of <=zero.
+
Rob to check if raw model produces lambda of <=zero.
  
 
Note: typical Vp speeds are 330 m/s in air, 1450 m/s in water and about 5000 m/s in granite
 
Note: typical Vp speeds are 330 m/s in air, 1450 m/s in water and about 5000 m/s in granite
Line 14: Line 15:
  
 
Frequency-independent Q definition
 
Frequency-independent Q definition
Qs=100*Vs(km/s)
+
Qs=100*Vs(km/s)
Qp=2*Qs
+
Qp=2*Qs
  
 
Frequencies (5Hz): based on 500 m/s and 20 m spacing
 
Frequencies (5Hz): based on 500 m/s and 20 m spacing

Revision as of 17:30, 5 March 2018

This page documents the High-F activities and decisions for the 2018 verification and validation runs for three groups: Olsen et al. (AWP), Graves (RWG) and Taborda et al. (Hercules).

Mesh Generation Rules and Parameter Constraints

Parameter constraints Velocities (fixing the CVM for meshing purposes)

  • 1. Set Min Vs=500 m/s
  • 2. If Vs was lower than 500 m/s and adjusted, then adjust Vp with original Vp/Vs ratio (so that we don’t have the automatic Vs/Vp of 3). We may want to set a minimum value of Vp (Rob to check)
  • 3. Then set Max Vp/Vs= 3, if lower Vp to maintain the max of 3 ratio

Lame parameters: mu and lambda (fixing the CVM for meshing purposes) Rob to check if raw model produces lambda of <=zero.

Note: typical Vp speeds are 330 m/s in air, 1450 m/s in water and about 5000 m/s in granite Lambda of zero corresponds to Vp/Vs= sqrt(2)=1.45;

Frequency-independent Q definition

  • Qs=100*Vs(km/s)
  • Qp=2*Qs

Frequencies (5Hz): based on 500 m/s and 20 m spacing Kim and Rob have been low-pass filtering the slip function at 5 Hz Ricardo and Naeem don’t filter the source


Source Models