Since most of the Hector Mine recordings have small amplitudes compared to CyberShake (PGA=0.02g to 0.3g), we also performed comparisons for 2 sites from Northridge (PGA=0.5g and 0.8g).  The calculated PGA values exactly matched those provided from PEER for the Northridge sites.  Full results are available [[File:CyberShake_Northridge_comparison.xlsx|here]].
+
Since most of the Hector Mine recordings have small amplitudes compared to CyberShake (PGA=0.02g to 0.3g), we also performed comparisons for 2 sites from Northridge (PGA=0.5g and 0.8g).  The calculated PGA values exactly matched those provided from PEER for the Northridge sites.  Input data is available [[File:NORTHRTest.zip|here]].  Full results are available [[File:CyberShake_Northridge_comparison.xls|here]].
  
 
In conclusion, the differences in the PGA results are small -- about the same as the differences we see when moving between systems -- and get smaller as the ground motions increase, so they are unlikely to have any meaningful impact on CyberShake curves.
 
In conclusion, the differences in the PGA results are small -- about the same as the differences we see when moving between systems -- and get smaller as the ground motions increase, so they are unlikely to have any meaningful impact on CyberShake curves.

Revision as of 20:02, 30 March 2020

CyberShake Study 20.5 is a CyberShake study in Southern California which uses Graves & Pitarka (2019) and includes stochastic high frequencies using the Graves & Pitarka high-frequency module from the SCEC Broadband Platform.

RotD code verification

We performed a verification exercise with the CyberShake RotD code. Christine selected 40 station recordings from Hector Mine (data File:HECTORTest.zip, and we calculated PGA and PGV by passing very small periods to the RotD50 code.

Full results of our Hector Mine tests are available here. Summary results are presented below:

Metric Average absolute percent difference (over 40 stations)
PGA, using period=1e-3 0.0165%
PGA, using period=1e-4 0.0118%
PGA, using period=1e-5 0.0118%
PGV, using period=1e-3 0.532%
PGV, using period=1e-4 0.526%

Since most of the Hector Mine recordings have small amplitudes compared to CyberShake (PGA=0.02g to 0.3g), we also performed comparisons for 2 sites from Northridge (PGA=0.5g and 0.8g). The calculated PGA values exactly matched those provided from PEER for the Northridge sites. Input data is available File:NORTHRTest.zip. Full results are available File:CyberShake Northridge comparison.xls.

In conclusion, the differences in the PGA results are small -- about the same as the differences we see when moving between systems -- and get smaller as the ground motions increase, so they are unlikely to have any meaningful impact on CyberShake curves.

Because the PGV results have such a higher difference than the PGA results, we suspected that the PEER-provided velocity seismograms weren't what PEER used to calculate their PGV. We decided to try integrating the acceleration seismograms ourselves and calculating PGV from those.

Metric Average absolute percent difference (over 40 stations)
PGV, using period=1e-4 and integrating with left rule 0.1306%
PGV, using period=1e-4 and integrating with trapezoid rule 0.0349%
PGV, using period=1e-4, trapezoid rule, and using g = 981 cm/s2 0.0%

This confirms that the RotD code is working correctly, and the issues with PGV agreement are because the PEER PGV values aren't actually calculated from their velocity seismograms.

Based on this work, we will use a period of 1e-4 to obtain CyberShake PGA and PGV using the RotD code.

Output Data Products

Seismograms

  • Deterministic (dt=0.05, nt=8000)
  • Broadband (dt=0.01, nt=40000)

Intensity Measures

Values for database

We will calculate and store the following intensity measures in the database (all PSA values are for 5% damping).

For deterministic seismograms (as simulated):

  • Store RotD50, RotD100 at the following 7 periods:
 10, 7.5, 5, 4, 3, 2, 1

For broadband seismograms (include minor site effects modifications):

  • Store RotD50, RotD100 in the database at the following 21 periods:
 10, 7.5, 5, 4, 3, 2, 1, 0.75, 0.5, 0.4, 0.3, 0.2, 0.1, 0.075, 0.05, 0.04, 0.03, 0.02, 0.01, PGA, PGV


Durations

Values for database

We will store the following durations in the database for broadband seismograms:

  • Acceleration significant duration based on Arias intensity at 5-75% and 5-95%, for both X and Y


Hazard Curves

We will calculate deterministic hazard curves at the following frequencies:

10, 5, 3, 2 sec

We will calculate broadband hazard curves at the following frequencies:

10, 5, 3, 2, 1, 0.5, 0.3, 0.2, 0.1 sec